– 10 –
TESTING THE GAS SUPPLY PIPING SYSTEM
When test pressures exceed
1
⁄2 psig (3.45 kPa), the fryer and its individual shutoff valve must be disconnected
from the gas supply piping system.
When test pressures are
1
⁄2 psig (3.45 kPa) or less, the fryer must be isolated from the gas supply piping system
by closing its individual shutoff valve.
LEVELING THE FRYER
Once gas connections have been made, place a spirit level on top of the fryer. Adjust the legs to ensure that
the fryer is level front-to-back and side-to-side in the final installed position.
FLUE CONNECTIONS
The fryer must be located under a hood which has an adequate connection to an exhaust duct. The hood must
extend 6" (15 cm) beyond fryer sides.
Adequate ventilation must be provided and must comply with NFPA Standard #96, (latest edition), and with local
codes.
Clearance above fryer should be adequate for products of combustion to be removed efficiently. An 18" (46 cm)
minimum clearance should be maintained between the flue vent and the filters of the hood venting system.
Never make flue connections directly to the fryer. Do not obstruct the flow of the flue gases from the flue duct
located at the rear of the appliance.
Adequate air should be provided in the kitchen to replace air taken out by the ventilating system. This will
prevent fryer function from being affected by a reduced atmospheric pressure.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE NATIONAL
ELECTRICAL CODE AND/OR OTHER LOCAL CODES.
WARNING: APPLIANCES EQUIPPED WITH ELECTRICAL SUPPLY CORD(S) ARE PROVIDED WITH A
THREE-PRONG GROUNDING PLUG WHICH MUST BE CONNECTED TO A PROPERLY GROUNDED
RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN
ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THE PLUG.
Some fryers (depending on options) are equipped with a 120 Volt/60 Hz./1 Phase cord and plug which requires
only that it be plugged into a properly grounded 120 volt receptacle.
Do not connect fryer to electrical supply until after gas connections have been made.