ELECTRICAL CONNECTIONS (see Fig. 3)
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE NATIONAL
ELECTRICAL CODE AND/OR OTHER LOCAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
The control box for field wire connection is located on the lower left side of the braising pan. A knockout hole is
provided for a 1" conduit connection.
1. Remove the control box cover plate. Mount suitable 1" conduit fitting in knockout opening.
2. Connect field wire to the terminal block as indicated on the wiring diagram. The wiring diagram is located on the
inside of the left door on closed base units and on the inside of the center door of open base units. Wire must be
of the type suitable for 75°C service, and of thickness as indicated on marking next to junction box.
3. After making the connections, replace the control box cover plate.
4. The braising pan must be grounded by installing a ground lead, properly grounded, to the ground lug located
inside the junction box.
ELECTRICAL DATA CHART
E30C/0 E40C/0
VOLTS PHASE K.W. AMP KW. LX LY LZ
208 1 10.2 49 13.6 65 65
240 1 13.5 57 18.0 75 75
208 3 10.2 29 13.6 43 43 29
240 3 13.5 33 18.0 50 50 33
480 3 13.5 17 18.0 25 25 17
These values are nominal ratings. Field wire connections must be capable of withstanding anticipated surges.
CONTROL CIRCUIT POWER CONNECTION All braising pans (see Fig's. 2 and 3)
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A
THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE CONNECTED INTO A
PROPERLY GROUNDED THREE-PRONG RECEPTACLE, IF THE RECEPTACLE IS NOT THE PROPER
GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THIS
PLUG.
This connection is not required on braising pans equipped with the optional step down transformer.
Connect a 120 volt, 50/60 Hz, 1 phase supply to the pigtail leads in the junction box located on the rear left of the
braising pan. Use copper wire suitable for 5 amperes and 75°C temperature. A ground wire must be connected to