OPERATION
WARNING: THE TILTING BRAISING PAN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,
CLEANING OR SERVICING THE BRAISING PAN.
BEFORE FIRST USE
Using a non-corrosive, grease-dissolving commercial cleaner, clean the protective metal oils from all surface parts and
the interior of the tilting braising pan. Follow the cleaner manufacturer's directions. Rinse thoroughly and drain the pan.
Wipe dry with a soft clean cloth.
GAS HEAT BRAISING PANS
Controls
Thermostat Maintains set temperature by controlling power supply.
On/Off Switch (Red) Standard braising pans with thermostatic temperature control located on a box on
the lower left corner of the braising pan. Braising pans with optional solid state
temperature control located on a box underneath the table top and behind the left
front door.
Pilot Switch (Optional) (Electronic Ignition Only.) When turned to ON, will initiate the electronic
ignition system.
Lighting and Shutdown of Pilot Standard Gas Braising Pan
Lighting instructions are also located on the back of one of the front doors.
1. Turn main gas supply to the braising pan ON at the shutoff valve.
2. To light the pilot, or to relight the pilot, turn thermostat and knob of combination control valve to OFF.
Wait 5 minutes before relighting.
3. Turn knob of combination control valve to PILOT. Depress this knob and light the pilot using a taper.
Pilot is located behind the hole identified with label "lighter and observation hole." Keep the knob
depressed for about one minute after lighting the pilot.
4. If there is no ignition, or if the pilot does not stay lit, the pilot flame may need to be adjusted. Remove
the cap covering the pilot adjustment screw on the combination control valve. Rotate exposed adjusting
screw counterclockwise one full turn. Then replace cap and repeat steps 1 through 3 above.
5. After pilot is lit, turn the knob of the combination control valve to the ON position.
6. Turn the red On/Off switch to ON. The ON position is indicated by a glowing red light on the switch.