LOCATION
For Gas Powered Braising Pans Only
The braising pan must be kept free and clear of combustible substances. The braising pan, when installed, must
have minimum clearance from combustible and non-combustible construction of 6" from the sides and 6" from the
rear.
The installation location must allow adequate clearances for servicing and proper operation. Recommended
clearances are 24" on the sides and back (for servicing), and 36" on the front. The ceiling should be at least 72"
from the floor.
The braising pan must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate
clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply
of air in the room suitable for the amount of combustion gas feeding the braising pan burners.
Do not permit fans to blow directly at the braising pan. Wherever possible, avoid open windows next to the braising
pan. Avoid wall-type fans which create air cross currents within the room.
Braising Pans Equipped with Casters
If casters are assembled to the braising pan, the installation must be made using a connector (not supplied by
Vulcan) that complies with the Standard for Connectors for Movable Gas Appliances, ANSI-Z21.69 (latest edition),
and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas
Fuel, ANSI-Z21.41 (latest edition). Provide a restraining device for the gas line to limit movement of the braising pan
without depending on the connector and/or any quick-disconnect device or its associated piping to limit braising pan
movement. Attach the restraint at the rear of the braising pan (Fig. 1).
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint
prior to turning the gas supply on and returning the braising pan to its originally installed position.
- 5 -