Vulcan-Hart 7595 Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
SERVICE (Cont.)
Main Burners: Ultra high input Bunsen type. See Detail 3.
Combination Automatic Valve: Combining regulator,
automatic pilot, and electric valve with single knob
control of pilot position, "ON" and "OFF" position.
Components of this value can be quickly removed for
service or replacement. The entire valve can be removed
as quickly, if necessary. "E" units use 120 volt 60 Hz
type. "G" units are millivolt type. Remove burners for
access to valve.
Auxiliary Shut Off Valve: All units have individual ser-
vice valve for shut off of gas supply to unit. This valve
permits servicing of individual unit without shut down of
gas supply to any other kitchen equipment.
Thermostats: Units are provided with Robertshaw Ther-
mostats, "E" models with KX type for 120 volts, "G"
models with GS type for MV control.
Drain Valves: Ball type. All steel construction. This type
valve does not require cleaning.
MAIN BURNER ORIFICES
Maximum
Input Per
Burner
Pressure
Reg.
Part No. Size Gas
32,500
BTU/hr.
32,500 BTU/hr.
5.5"W.C.
10.0"W.C.
10901-
35
10901-51
No.
35 (.110)
No. 51 (.067)
Natural
Propane
PILOT BURNERS
Item Part No. Gas
Orifice
Robertshaw No.
Used On
1
2
112082-
1
112082-2
Natural
Propane
.016 3CH-10
.010 3CH-10
"E"&"G" Models
"E"&“G" Models
THERMOPILE - 500 MILLIVOLT
3 110839-1 Nat., Propane & Mixed DNA 51023 "E"&"G" Models
114590-6
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 26 27

Comentarios a estos manuales

Sin comentarios