TESTING (Cont.)
2. Turn the thermostat knob to a medium temperature setting.
3. Allow enough time for temperature to stabilize, or until
several temperature readings are identical.
4. Read thermometer to see if it agrees with dial setting. The
difference between dial setting and thermometer reading
should not be more than 3% of the total temperature range
on the thermostat dial.
5. If difference in reading is more than 3%, recalibrate the
thermostat as follows:
a) Remove thermostat knob.
b) Rotate screw-in stem clockwise to decrease and coun-
terclockwise to increase temperature. 1/4 turn equals 18°,
c) Replace knob, reset medium temperature setting, and
recheck.
FRY TANK REPLACEMENT PROCEDURE
1. Turn thermostat to "OFF". Unplug electric cord on "E"
models.
2. Drain frytank.
3. Lift off basket hanger. Remove baskets and crumb screen.
4. Remove burners.
5. Turn service valve "OFF".
6. Disconnect pilot burner and demount from tank.
7. Remove thermostat bulb and high limit bulb, through fittings
in bottom of frytank.
8. Tank with flue box attached can now be lifted out of unit.
NOTE: Transfer flue box from old tank to new when replacing
tank.
114590-8