6. Unplug drain valve interlock switch from wiring
harness and remove switch from fryer.
7. Reverse procedure to install and check for proper
operation.
FRY TANK
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Remove BURNER ASSEMBLY.
2. Remove both HIGH LIMIT THERMOSTAT and
TEMPERATURE [ROBE.
3. Remove DRAIN VALVE INTERLOCK SWITCH.
4. Remove drain assembly from drain valve.
A. Remove hose clamp from rubber boot.
B. Remove drain piping from drain valve.
Fig. 41
5. Remove drain valve from fry tank.
Fig. 42
6. Loosen and disconnect the oil return line, if
equipped with filter system.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - REMOVAL AND REPLACEMENT OF PARTS
F45474 (0413) Page 22 of 54