ELECTRIC STATIONARY KETTLES
ELECTRICAL SPECIFICATIONS
Amperage per Line Minimum
MODEL kW PHASE Circuit Ampacity
208V 240V 480V 208V 240V 480V
K20EL/ELT 12 1 57.7 75
3 33.3 14.4 45 20
16 1 66.7 85
3 38.5 50
K40EL/ELT
18 3 50.0 43.3 21.7 65 55 30
K60EL/ELT
K40EL/ELT
24 3 66.6 57.7 28.9 85 75 40
K60EL/ELT
K60EL/ELT 33 3 91.6 79.4 39.7 115 100 50
ELECTRICAL CONNECTION
: Electrical and ground-
ing connections must comply with appli-
cable portions of the National Electric
Code and/or other local electrical codes.
Disconnect
electrical power to the
machine and follow Lockout/
Tagout procedures.
1. Open the control box.
2. Using the wiring diagram for reference,
connect electric supply to terminal block.