ELECTRIC STATIONARY KETTLES
TROUBLESHOOTING
PROBLEM
Unit not Heating
Unit not heating to
desired temperature
Draw valve is leaking
POSSIBLE CAUSES / SUGGESTED CORRECTIVE ACTION
ON/OFF switch OFF / ON/OFF switch ON.
Thermostat not on / Turn thermostat on.
No power / Check power supply.
Water level too low / Add water.
Malfunctioning power ON/OFF switch / Contact Authorized
Vulcan-Hart Service Provider.
Malfunctioning thermostat / Contact Authorized Vulcan-Hart
Service Provider.
Contactors not connecting heating element to power source / Contact
Authorized Vulcan-Hart Service Provider.
Thermostat not on / Turn thermostat on.
Malfunctioning thermostat / Contact Authorized Vulcan-Hart
Service Provider.
Check and clean any food residue with an extremely fine emery cloth.
Replace the “O” ring.