F-35641 (2-05)
- NOTICE -
This manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly qualified.
If you have attended a Vulcan Service School for this product, you
may be qualified to perform all the procedures described in this
manual.
This manual is not intended to be all encompassing. If you have not
attended a Vulcan Service School for this product, you should
read, in it's entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
SERVICE MANUAL
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanhart.com
EF SERIES
GAS FRYERS
MODELS
EF3 ML-52099
EF4 ML-114943
EF5 ML-114944
VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM
P.O. BOX 696, LOUISVILLE, KY 40201-0696
TEL. (502) 778-2791
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - SERVICE MANUAL

F-35641 (2-05)- NOTICE -This manual is prepared for the use of trained Vulcan ServiceTechnicians and should not be used by those not properly qualifie

Pagina 2

— 10 —F35641 (02-05)EF SERIES GAS FRYERSCOMBINATION VALVEWARNING: SHUT OFF THE GAS BEFORESERVICING.WARNING: ALL GAS JOINTS DISTURBEDDURING SERVICING M

Pagina 3

— 11 —F35641 (02-05)EF SERIES GAS FRYERSFRY TANKWARNING: SHUT OFF THE GAS BEFORESERVICING.WARNING: ALL GAS JOINTS DISTURBEDDURING SERVICING MUST BE CH

Pagina 4 - COVERS AND PANELS

— 12 —F35641 (02-05)EF SERIES GAS FRYERSMILLIVOLT CONTROLS TEST1. Verify proper gas (natural or propane) ispresent.2. Check for correct wiring and sec

Pagina 5 - THERMOSTAT

— 13 —F35641 (02-05)EF SERIES GAS FRYERS5. Allow temperature to stabilize at newsetting and compare temperature testerto dial setting. Recalibrate if

Pagina 6

— 14 —F35641 (02-05)EF SERIES GAS FRYERS2. Hold the burner nozzle with channel locksand remove the orifice, (Figure 22). Checkthe orifice for obstruct

Pagina 7

— 15 —F35641 (02-05)EF SERIES GAS FRYERS6. Read the pressure gauge. The manifoldpressure reading should match thepressure rating on the data plate.A.

Pagina 8 - THERMOPILE

— 16 —F35641 (02-05)EF SERIES GAS FRYERSCONTROL SYSTEMDESCRIPTION1. The thermopile (PG) provides the totalcontrol voltage for this system.A. One side

Pagina 9 - PILOT ORIFICE

— 17 —F35641 (02-05)EF SERIES GAS FRYERSSYSTEM CONDITION QUICKCHECK PROCEDURES1. Use the Pilot Lighting procedure andcheck millivolts (mV) at wires 3

Pagina 10 - COMBINATION VALVE

— 18 —F35641 (02-05)EF SERIES GAS FRYERSTROUBLESHOOTINGSYMPTOMThe temperature of theshortening drops, orexcessive recovery time isrequired.Pilot won’t

Pagina 11 - FRY TANK

— 19 —F35641 (02-05)EF SERIES GAS FRYERSSYMPTOMLeaking tank.Pilot burner flamesadjusted properly, butfluctuates to very low andblows out easily.CAUSEF

Pagina 12 - THERMOSTAT CALIBRATION

— 2 —F35641 (02-05)EF SERIES GAS FRYERSCONTENTSGENERAL ...

Pagina 13 - AND ORIFICES

F35641 (02-05)PRINTED IN U.S.A.

Pagina 14 - REGULATOR ADJUSTMENT

— 3 —F35641 (02-05)EF SERIES GAS FRYERSGENERALINTRODUCTIONModelsThis service manual was written for:EF3, EF4 and EF5 Gas Fryers.INSTALLATIONGenerally,

Pagina 15 - EF SERIES GAS FRYERS

— 4 —F35641 (02-05)EF SERIES GAS FRYERSCOVERS AND PANELSWARNING: SHUT OFF THE GAS BEFORESERVICING.Door1. While holding onto the door remove (2)screws

Pagina 16

— 5 —F35641 (02-05)EF SERIES GAS FRYERSBURNERSWARNING: SHUT OFF THE GAS BEFORESERVICING.1. Remove heat shield as outlined underCover and Panels. (Opti

Pagina 17 - COMPONENT FUNCTION

— 6 —F35641 (02-05)EF SERIES GAS FRYERS5. Remove thermostat mounting screws andremove thermostat from mounting bracket(Figure 5).Figure 56. Remove wir

Pagina 18 - TROUBLESHOOTING

— 7 —F35641 (02-05)EF SERIES GAS FRYERS10. Reverse the procedure to install. Wheninstalling the new thermostat assembly,do not kink the thermostat cap

Pagina 19

— 8 —F35641 (02-05)EF SERIES GAS FRYERS8. Pull the high limit bulb through theunderside of the fry tank and remove thehigh limit.9. Reverse the proced

Pagina 20 - PRINTED IN U.S.A

— 9 —F35641 (02-05)EF SERIES GAS FRYERS3. Remove thermopile from pilot bracket byloosening the holding nut (Figure 13).Figure 134. Reverse procedure t