A product of VULCAN-HART LOUISVILLE, KY 40201-0696
F25125 (March 2003)
- NOTICE -
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this
product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
GR35 SHOWN
SERVICE MANUAL
GR SERIES GAS FRYERS WITH
MILLIVOLT CONTROLS
MODEL ML MODEL ML
GR25 126988 GR35F 126998
GR35 126989 GR45F 126999
GR45 126990 GR65F 135534
GR65 126991 GR85F 135535
GR85 126992
For additional information on Vulcan-Hart Company or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanhart.com.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - SERVICE MANUAL

A product of VULCAN-HART LOUISVILLE, KY 40201-0696F25125 (March 2003)- NOTICE -This Manual is prepared for the use of trained Vulcan ServiceTechnician

Pagina 2 - TABLE OF CONTENTS

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003) Page 10 of 243. Reverse procedure to install and check forproper operatio

Pagina 3 - BATTERY FRYERS

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003)Page 11 of 2421. Reverse procedure to install all the partsremoved from or

Pagina 4

GR SERIES GAS FRYERS - SERVICE PROCEDURES AND ADJUSTMENTSF25125 (March 2003) Page 12 of 24SERVICE PROCEDURES AND ADJUSTMENTSWARNING: CERTAIN PROCEDUR

Pagina 5 - FRONT PANEL

GR SERIES GAS FRYERS - SERVICE PROCEDURES AND ADJUSTMENTSF25125 (March 2003)Page 13 of 24NON FILTER READY SHOWNGAS MANIFOLD PRESSUREADJUSTMENTWARNING

Pagina 6 - HIGH LIMIT THERMOSTAT

GR SERIES GAS FRYERS - SERVICE PROCEDURES AND ADJUSTMENTSF25125 (March 2003) Page 14 of 24NON FILTER READY SHOWNA. If adjustment is necessary, contin

Pagina 7 - MAIN BURNERS

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003)Page 15 of 24ELECTRICAL OPERATIONCOMPONENT FUNCTIONFRYER CONTROLSControl Thermostat ...

Pagina 8 - GAS COMBINATION VALVE

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003) Page 16 of 24GR35 NON FILTER READY SHOWNGR45 FILTER READY SHOWN2GR45F KLEENSCREEN FRYE

Pagina 9 - THERMOPILE

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003)Page 17 of 24SEQUENCE OF OPERATIONMillivolt ControlsRefer to schematic diagram 7825. 1.

Pagina 10 - FRY TANK ASSEMBLY

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003) Page 18 of 24SCHEMATIC DIAGRAMMillivolt Controls

Pagina 11 - PUMP AND MOTOR

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003)Page 19 of 24WIRING DIAGRAMSMillivolt Controls

Pagina 12 - CALIBRATION

GR SERIES GAS FRYERSF25125 (March 2003) Page 2 of 24TABLE OF CONTENTSGENERAL ...

Pagina 13 - ADJUSTMENT

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003) Page 20 of 24Junction Box, Kleenscreen Filtering System

Pagina 14 - MILLIVOLT CONTROLS TEST

GR SERIES GAS FRYERS - ELECTRICAL OPERATIONF25125 (March 2003)Page 21 of 24Frymate (Dump Station)

Pagina 15 - ELECTRICAL OPERATION

GR SERIES GAS FRYERS - TROUBLESHOOTINGF25125 (March 2003) Page 22 of 24TROUBLESHOOTINGALL MODELSSYMPTOMS POSSIBLE CAUSESPilot burner will not light.

Pagina 16 - COMPONENT LOCATION

GR SERIES GAS FRYERS - TROUBLESHOOTINGF25125 (March 2003)Page 23 of 24FRYMATE (DUMP STATION)WITH OPTIONAL HEATERSYMPTOM POSSIBLE CAUSESNo heat. 1. Un

Pagina 17 - SEQUENCE OF OPERATION

GR SERIES GAS FRYERS - CONDENSED SPARE PARTS LISTF25125 (March 2003) Printed in U.S.A.CONDENSED SPARE PARTS LISTKLEENSCREEN FILTERPART NUMBER DESCRIPT

Pagina 18 - SCHEMATIC DIAGRAM

GR SERIES GAS FRYERS - GENERALF25125 (March 2003)Page 3 of 24GENERALINTRODUCTIONThis Service Manual covers specific service information related to th

Pagina 19 - WIRING DIAGRAMS

GR SERIES GAS FRYERS - GENERALF25125 (March 2003) Page 4 of 24KLEENSCREEN FILTERINGSYSTEMThe new Kleenscreen filtering system has beenintegrated into

Pagina 20

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003)Page 5 of 24SPECIFICATIONSElectrical• 120VAC supply for Filter-Ready fryer

Pagina 21 - Frymate (Dump Station)

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003) Page 6 of 24NON FILTER READY SHOWN2. When replacing door, install screws

Pagina 22 - TROUBLESHOOTING

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003)Page 7 of 245. Remove the capillary tube retaining and packingnuts, from t

Pagina 23 - KLEENSCREEN FILTERING

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003) Page 8 of 24NON FILTER READY SHOWN4. Reverse procedure to install.MAIN BU

Pagina 24 - CONDENSED SPARE PARTS LIST

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTSF25125 (March 2003)Page 9 of 246. Reverse procedure to install and check forproper operation.